You can adjust the steel cladding settings in the hall settings dialog Settings tab. Covering settings can be made separately for the right, left, top, front and back parts of the hall in the Settings tab.
Location of Steel Cladding Settings
Select the hall where you want to change the steel cladding settings and click the right mouse button. Click the Properties line from the right click menu that opens.
General Settings Tab
Features | Description |
---|---|
Section | The profile used appears. One of the previously defined profiles can be selected by clicking the list, or a new profile can be selected from the dialog that opens when the Load Section button is clicked. |
Object name | The name of the coating in the project. |
Color | Overlay is the color of the border lines. The selection is made on the color palette that is opened by clicking with the left mouse button and holding the button down. |
Materiel | In the solid model of the coating, the material to be covered is selected. It is coated with the selected material and displayed as such in the solid model. |
Actual tissue length | Texture length is entered. For example; If 1 meter is entered, the selected material texture is taken as 1 meter and covered on the selected object. If the texture is thought to be in the form of a square, the object surfaces are covered with 1x1 textures arranged side by side. |
Structural Tab
Features | Description |
---|---|
Unit weight | The unit weight of the coating is entered according to the material used. |
Snow load | If available, the snow load is entered. |
Live load | Select the appropriate value for live load from the list. The values that appear in the list are the values defined in the slab load library. If you are going to use another value instead of using one value from the list, select "user-defined" from the list and enter a value. |
User defined wind loads | Depending on demand, wind load can be entered on the coating elements in desired direction |