How does ideCAD control increased structural height limits according to ASCE 7-16?
The software controls the Increased structural height limit automatically according to ASCE 7-16 12.2.5.4.
Design coefficients and factors selected by the user in the analysis settings wizard are checked automatically, and the results are reported.
Structural system selection, Response modification coefficient R, Deflection amplification factor Cd and Overstrength factor Ωo are defined by the user.
Using the ASCE 7-16 Wizard, instructions are made by the user.
SYMBOLS
Cd = Deflection amplification factor
Ωo = Overstrength factor
R = Response modification coefficient
Increased Structural Height Limit for Steel Eccentrically Braced Frames, Steel Special Concentrically Braced Frames, Steel Buckling-Restrained Braced Frames, Steel Special Plate Shear Walls, and Special Reinforced Concrete Shear Walls
The limits on structural height, hn, are given in Table 12.2-1, shown below.
It has permitted to be increased from 160 ft (50 m) to 240 ft (75 m) for structures assigned to Seismic Design Categories D or E and from 100 ft (30 m) to 160 ft (50 m) for structures assigned to Seismic Design Category F, on condition that the seismic force-resisting systems are limited to steel eccentrically braced frames, steel special concentrically braced frames, steel buckling restrained braced frames, steel special plate shear walls, or special reinforced concrete cast-in-place shear walls.
Structural System Type | Response Modification Coefficient, R | Overstrengh Factor, Ωo | Deflection Amplification Factor, Cd | Structural System Limitations Including Structural Height, hn (ft) Limits | ||||
---|---|---|---|---|---|---|---|---|
Seismic Design Category | ||||||||
B | C | D | E | F | ||||
A. Bearing Wall Systems | ||||||||
A1 - Special reinforced concrete shear walls | 5 | 21/2 | 5 | NL | NL | 160 | 160 | 100 |
A2 - Ordinary reinforced concrete shear walls | 4 | 21/2 | 4 | NL | NL | NP | NP | NP |
A3 - Detailed plain concrete shear walls | 2 | 21/2 | 2 | NL | NP | NP | NP | NP |
A4 - Ordinary plain concrete shear walls | 11/2 | 21/2 | 11/2 | NL | NP | NP | NP | NP |
B. Building Frame Systems | ||||||||
B1 - Steel eccentrically braced frames | 8 | 2 | 4 | NL | NL | 160 | 160 | 100 |
B2 - Steel special concentrically braced frames | 6 | 2 | 5 | NL | NL | 160 | 160 | 100 |
B3 - Steel ordinary concentrically braced frames | 31/4 | 2 | 31/4 | NL | NL | 35 | 35 | NP |
B4 - Special reinforced concrete shear walls | 6 | 21/2 | 5 | NL | NL | 160 | 160 | 100 |
B5 - Ordinary reinforced concrete shear walls | 5 | 21/2 | 41/2 | NL | NL | NP | NP | NP |
B6 - Detailed plain concrete shear walls | 2 | 21/2 | 2 | NL | NP | NP | NP | NP |
B7 - Ordinary plain concrete shear walls | 11/2 | 21/2 | 11/2 | NL | NP | NP | NP | NP |
C. Moment-Resisting Frame Systems | ||||||||
C1 - Steel special moment frames | 8 | 3 | 51/2 | NL | NL | NL | NL | NL |
C2 - Steel special truss moment frames | 7 | 3 | 51/2 | NL | NL | 160 | 100 | NP |
C3 - Steel intermediate moment frames | 41/2 | 3 | 4 | NL | NL | 35 | NP | NP |
C4 - Steel ordinary moment frames | 31/2 | 3 | 3 | NL | NL | NP | NP | NP |
C5 - Special reinforced concrete moment frames | 8 | 3 | 51/2 | NL | NL | NL | NL | NL |
C6 - Intermediate reinforced concrete moment frames | 5 | 3 | 41/2 | NL | NL | NP | NP | NP |
C7 - Ordinary reinforced concrete moment frames | 3 | 3 | 21/2 | NL | NP | NP | NP | NP |
D. Dual Systems with Special Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces | ||||||||
D1 - Steel eccentrically braced frames | 8 | 21/2 | 4 | NL | NL | NL | NL | NL |
D2 - Steel special concentrically braced frames | 7 | 21/2 | 51/2 | NL | NL | NL | NL | NL |
D3 - Special reinforced concrete shear walls | 7 | 21/2 | 51/2 | NL | NL | NL | NL | NL |
D4 - Ordinary reinforced concrete shear walls | 6 | 21/2 | 5 | NL | NL | NP | NP | NP |
E. Dual Systems with Intermediate Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces | ||||||||
E1 - Steel special concentrically braced frames | 6 | 21/2 | 5 | NL | NL | 35 | NP | NP |
E2 - Special reinforced concrete shear walls | 61/2 | 21/2 | 5 | NL | NL | 160 | 100 | 100 |
E8 - Ordinary reinforced concrete shear walls | 51/2 | 21/2 | 41/2 | NL | NL | NP | NP | NP |
F. Shear Wall-Frame Interactive System with Ordinary Reinforced Concrete Moment Frames And Ordinary Reinforced Concrete Shear Walls | ||||||||
F1 - Shear wall-frame interactive system | 41/2 | 21/2 | 4 | NL | NP | NP | NP | NP |
G. Cantilevered Column Systems Detailed to Conform to the Requirement for | ||||||||
G1 - Steel special cantilever column systems | 21/2 | 11/4 | 21/2 | 35 | 35 | 35 | 35 | 35 |
G2 - Steel ordinary cantilever column systems | 11/4 | 11/4 | 11/4 | 35 | 35 | NP | NP | NP |
G3 - Special reinforced concrete moment frames | 21/2 | 11/4 | 21/2 | 35 | 35 | 35 | 35 | 35 |
G4 - Intermediate reinforced concrete moment frames | 11/2 | 11/4 | 11/2 | 35 | 35 | NP | NP | NP |
G5 - Ordinary reinforced concrete moment frames | 1 | 11/4 | 1 | 35 | NP | NP | NP | NP |
H. Steel Systems not Specifically Detailed for Seismic Resistance, Excluding Cantilever Column Systems | ||||||||
H - Steel Systems not Specifically Detailed for Seismic Resistance | 3 | 3 | 3 | NL | NL | NP | NP | NP |