Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 11 Current »

How does ideCAD control increased structural height limits according to ASCE 7-16?


  • The software controls the Increased structural height limit automatically according to ASCE 7-16 12.2.5.4.

  • Design coefficients and factors selected by the user in the analysis settings wizard are checked automatically, and the results are reported.

  • Structural system selection, Response modification coefficient R, Deflection amplification factor Cd and Overstrength factor Ωo are defined by the user.


SYMBOLS

Cd = Deflection amplification factor
Ωo = Overstrength factor
R = Response modification coefficient


Increased Structural Height Limit for Steel Eccentrically Braced Frames, Steel Special Concentrically Braced Frames, Steel Buckling-Restrained Braced Frames, Steel Special Plate Shear Walls, and Special Reinforced Concrete Shear Walls

The limits on structural height, hn, are given in Table 12.2-1, shown below.

It has permitted to be increased from 160 ft (50 m) to 240 ft (75 m) for structures assigned to Seismic Design Categories D or E and from 100 ft (30 m) to 160 ft (50 m) for structures assigned to Seismic Design Category F, on condition that the seismic force-resisting systems are limited to steel eccentrically braced frames, steel special concentrically braced frames, steel buckling restrained braced frames, steel special plate shear walls, or special reinforced concrete cast-in-place shear walls.

Structural System Type

Response Modification Coefficient, R

Overstrengh Factor, Ωo

Deflection Amplification Factor, Cd

Structural System Limitations Including Structural Height, hn (ft) Limits

Seismic Design Category

B

C

D

E

F

A. Bearing Wall Systems

A1 - Special reinforced concrete shear walls

5

21/2

5

NL

NL

160

160

100

A2 - Ordinary reinforced concrete shear walls

4

21/2

4

NL

NL

NP

NP

NP

A3 - Detailed plain concrete shear walls

2

21/2

2

NL

NP

NP

NP

NP

A4 - Ordinary plain concrete shear walls

11/2

21/2

11/2

NL

NP

NP

NP

NP

B. Building Frame Systems

B1 - Steel eccentrically braced frames

8

2

4

NL

NL

160

160

100

B2 - Steel special concentrically braced frames

6

2

5

NL

NL

160

160

100

B3 - Steel ordinary concentrically braced frames

31/4

2

31/4

NL

NL

35

35

NP

B4 - Special reinforced concrete shear walls

6

21/2

5

NL

NL

160

160

100

B5 - Ordinary reinforced concrete shear walls

5

21/2

41/2

NL

NL

NP

NP

NP

B6 - Detailed plain concrete shear walls

2

21/2

2

NL

NP

NP

NP

NP

B7 - Ordinary plain concrete shear walls

11/2

21/2

11/2

NL

NP

NP

NP

NP

C. Moment-Resisting Frame Systems

C1 - Steel special moment frames

8

3

51/2

NL

NL

NL

NL

NL

C2 - Steel special truss moment frames

7

3

51/2

NL

NL

160

100

NP

C3 - Steel intermediate moment frames

41/2

3

4

NL

NL

35

NP

NP

C4 - Steel ordinary moment frames

31/2

3

3

NL

NL

NP

NP

NP

C5 - Special reinforced concrete moment frames

8

3

51/2

NL

NL

NL

NL

NL

C6 - Intermediate reinforced concrete moment frames

5

3

41/2

NL

NL

NP

NP

NP

C7 - Ordinary reinforced concrete moment frames

3

3

21/2

NL

NP

NP

NP

NP

D. Dual Systems with Special Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces

D1 - Steel eccentrically braced frames

8

21/2

4

NL

NL

NL

NL

NL

D2 - Steel special concentrically braced frames

7

21/2

51/2

NL

NL

NL

NL

NL

D3 - Special reinforced concrete shear walls

7

21/2

51/2

NL

NL

NL

NL

NL

D4 - Ordinary reinforced concrete shear walls

6

21/2

5

NL

NL

NP

NP

NP

E. Dual Systems with Intermediate Moment Frames Capable of Resisting at Least 25% of Prescribed Seismic Foces

E1 - Steel special concentrically braced frames

6

21/2

5

NL

NL

35

NP

NP

E2 - Special reinforced concrete shear walls

61/2

21/2

5

NL

NL

160

100

100

E8 - Ordinary reinforced concrete shear walls

51/2

21/2

41/2

NL

NL

NP

NP

NP

F. Shear Wall-Frame Interactive System with Ordinary Reinforced Concrete Moment Frames And Ordinary Reinforced Concrete Shear Walls

F1 - Shear wall-frame interactive system

41/2

21/2

4

NL

NP

NP

NP

NP

G. Cantilevered Column Systems Detailed to Conform to the Requirement for

G1 - Steel special cantilever column systems

21/2

11/4

21/2

35

35

35

35

35

G2 - Steel ordinary cantilever column systems

11/4

11/4

11/4

35

35

NP

NP

NP

G3 - Special reinforced concrete moment frames

21/2

11/4

21/2

35

35

35

35

35

G4 - Intermediate reinforced concrete moment frames

11/2

11/4

11/2

35

35

NP

NP

NP

G5 - Ordinary reinforced concrete moment frames

1

11/4

1

35

NP

NP

NP

NP

H. Steel Systems not Specifically Detailed for Seismic Resistance, Excluding Cantilever Column Systems

H - Steel Systems not Specifically Detailed for Seismic Resistance

3

3

3

NL

NL

NP

NP

NP


  • No labels