When the site class is F, spectral acceleration parameters and site coefficients should be entered by users from the Response spectrum section in the analysis settings.
A selection is made from the table according to the local soil class given in the site survey report prepared in accordance with ASCE 7-16 Table 20.3-1. If the site class is F, data entry is made from the Analysis Settings / Response Spectrum tab.