Click the Tools / Geometry Control line in the classic menu and the Tools / Tools / Geometry Control icon in the ribbon menu .
In the dialog that appears on the screen, mark the conditions to be checked for geometry, specify whether the control will be made for all floors and enter the minimum object length (Zero value means no length control).
Click the OK button. The program will report whether problem situations are found or not, and list problematic objects, if any.
...
Minimum object Min. entity length: Lengths of short walls, short beams and short continuous foundations strips min. will be compared with the object length and objects shorter than this length will be marked.
Apply to all floorsPerform check at all stories: If checked, controls will be made for all floorsstories.
Short objectsentities: When checked, if there are objects with smaller openings than the value entered in the Minimum Object Min. Entity Length line, the program lists these objects.
Overlapping objectsentities: Lists overlapping objects.
Column/beam-curtain panel intersections: If there are beams, walls and columns that are intersecting each other and not statically related, they are listed. This is due to the beam or curtain shearwall not coming into contact with the column.
Vertical continuitysupport consistency: It checks the case of vertical elements such as columns and walls to be cut in intermediate floors stories and forming faulty foundations. It occurs when the elevations of columns and curtains shearwalls or element misalignments are given incorrectly.
Objects Entities with the same nameID: Detects objects with the same names. Check the necessity of the object with the same name.
The floors Slabs with insufficient and incorrect calculation or invalid concrete axis: In static floorsslabs, it is reported when the calculation axis is not drawn or it is drawn in only one direction.
Floor levelsStatic slab elevations: Controls the relationship between floors slabs and beams. For example, if the level of a slab is given in a way that it does not connect to any beam, this error is encountered.
Unfracted beamsBeams without support: The beams whose two ends are unloaded are checked. The beam must be attached to another element at at least one point.
Check sloping floorsinclined slabs: Checks whether the floors are entered in accordance with the rules in sloping systems such as roof tiles.
Cassette Ribbed and rib flooringwaffle slabs: It checks the presence of the caliper and the continuity within itself, which is necessary for the solution of cassette waffle and rib flooringribbed slab.
Static properties user-defined elementsoverriden entities: List the objects whose section parameters have been modified.
Incorrect objects with static materials Entities with invalid structural material: Lists objects for which no static material definition has been made.
Possible objects Entities placed at with possible wrong angle: List minor angle objects. Check if the angles of these objects are suitable for the project.
Faulty Check entities according to codes: When the option is selected, the conformity of the objects according to TDY 2007 and TS500 is checked. For example, floor height control is done according to the formula given in TS500.
Invalid doors/windows: It is checked whether the doors/windows are inside the wall.
...