With automatic namingauto label entities command, you can name the entire structure at once or only the selected element or element groups.
Table of Contents |
---|
...
Location of Auto
...
Label Entities Command
You can access the name object command under the ribbon menu Change Modify tab Object Entity Edit title.
...
Auto
...
Label Options
...
Specifications | ExplainedDescriptions |
---|---|
Naming Select labeling methodselection
| With the “Name objects on this floor” “Generate labels for this story” option, it only names the objects on the working floor. Name the objects on the other floor considering the objects on the current floor, and With the “Set othe stories' labels by assuming this story as base for same entities” option, it names the elements on the other floors to be the same as the elements on the floor being studied. When naming the object by creating the incompatible objects from the object names on the other floors, the position of the said With the “Generate other stories' labels for unmathced entities”, element on the other floors is stories are checked. |
Naming schemeModify labeling settings | While renaming with "re-name"labeling with reset, all names of the selected elements return to the project default. Store names in memory Labelling will continue at the end of the process, stores the names given to the elements in memory and reuses them in new naming. |
Name curtains in one directionTreat shearwalls as 1D entity | Name the curtains shearwalls in one direction, regardless of the direction, when the curtains shearwalls come. |
Auto
...
Label Objects Settings
...
Specifications | ExplainedDescriptions |
---|---|
Object Entity list | Naming settings are opened by selecting the objects from the list. |
First nameInitial ID | The initial (first) name of the object to be named is entered. For example, if S1 is given, the objects are named as S1, S2, S3 while processing. |
Naming criteriaScan
| In an angle system with the angle option, if you want to make a naming according to the angle, the relevant angle value is entered on this line. For example, in a system connected by 45 degree axes, the value 45 is entered in this line to make a name that takes 45 degrees into account. While naming with the Tolerance option, it determines which of the objects that are close to each other will be selected first, with the tolerance entered on this line. The closest object remaining within the length value entered in this line is named first. |
Main direction / Other directionLabeling directions major/minor scan | The direction and direction in which the naming process will be done is selected first. |
Name Label by axis | With this option that is valid for columns, you can name the columns with the names of the axis passing through the column. For example, A and 1 axes are defined in the column. If the prefix S is given, the column is named SA1. |
...
Usage Steps
Click the Auto Name ObjectsLabel Entities icon in the ribbon menu .
The naming method and naming scheme settings are set in the automatic naming auto label options dialog.
Select the objects you want to name.
Enter the first name (P1, K1, P13, K4 etc.) to be used for naming in the Auto -name objects label entities dialog. Select naming criteria and main direction and click the OK button.
Selected objects will be named automatically according to their direction preferences.
Process step | Object naming in the plan |
---|---|
Before automatic object namingauto label entities | |
After automatic object namingauto label entities (The main direction is from bottom to top, the other direction is from right to left) |
...