a ≥ a min     

ÇYTHYEDY 13.3.7

 

 

a

8 mm

 

a min

4 mm

Table 13.4

Connection Detail

...

Prequalification Limits (TBDY Table 9B.2)

Beam span / Beam cross-section height

9144 mm /550 mm=16.63

≥9.0

Beam cross-section height, d b

550 mm

≤ 920

Beam head thickness, t bf

17.2 mm

≤25

Column cross section height

650 mm

≤ 920 mm

Bolt class

8.8

8.8 - 10.9

Bolt size

M27

≤ M27

Min yield stress of header plate material

275 MPa

235 /275 / 355 MPa

Title plate welding

CJP