  • Since the foundation is a flooring slab element that works in two directions, the sum of the reinforcement ratios in both directions cannot be less than 0.0035 for B420C, provided that it is not less than 0.0015 in each direction, as required by TS 500 11.4.5. The range of reinforcement cannot be more than 200 mm.

...