Sample Foundation Design
Sample Foundation Design
According to TS 500, the minimum bending and shear reinforcement of the foundation will be determined first. The element strengths obtained with these reinforcements will be compared with the design forces obtained from the calculation. If the strength values are smaller than the design forces, the required element strength will be obtained by revising the foreseen reinforcements.
Determination of Internal Forces Acting on Foundations (4.10.3)
The raft foundation was used in the building and the upper structure interactive solution was applied. In the raft foundation report, loads from the upper section to the foundation and their calculations are reported as follows.