This message is created by specifying the element name and floor on which it is located at the beginning of the report.

For example,

SB001 BASE STORY Composite beam strength not satisfied.

This warning is given if the following design conditions are not met in the steel composite beam design.

  • The bending moment design ratio during the construction phase should be below 1.00.

  • The composite bending moment design ratio should be below 1.00.

  • The cutting force design ratio should be below 1.00.

Possible Solutions:

  • The cross-sectional dimensions of the secondary beam element, whose name and floor are given, can be enlarged.

  • The load per secondary beam can be reduced by reducing the secondary beam spacing.

  • The compositeness rate can be increased by increasing the number of shear nails.

...