Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Specifications

Wall load

The appropriate wall load is selected from the list. The wall loads in the list are those defined in the load library. If you want to specify a value other than these values ​​as wall load, the user defined line is selected from the list and the appropriate value is given. The value should be defined as the weight per 1 meter of the wall above the beam.

Wall height

The height of the wall can be determined on request. The length of the clean wall should be subtracted from the story height and the beam heights in the story. If the wall height is determined by the user, the wall load will be calculated according to this height and the determined wall unit weight.

Automatic wall height

If the option is selected, the program automatically calculates the clean wall length by subtracting the beam height from the story height according to the set offset of the relevant beams and uses this height when calculating the fixed load.

Live load

It is the extra additional live load that can be defined on the beam. It can be used if extra load is defined outside the system to the beam. The appropriate value is selected from the list. The loads in the list are those defined in the load library. If you want to specify a value other than these values ​​as load, the user defined line is selected from the list and the appropriate value is given.

Curvature Tab

...

Specifications

Radius of curvature

image-20240205-110831.pngImage Modified

The radius value is given according to the center of the arc segment based on the height of the column. Negative value will create curvature to the other side.

Apex height

image-20240205-111003.pngImage Modified

The height value is given according to the middle height of vault element, middle axis height of curvature element.

Angle difference between segments

image-20240205-112233.pngImage Modified

The precision angle used when creating curvature. As sensitivity increases, processing speed decreases.

Bending plane

image-20240205-110804.pngImage Modified

It is determined whether the curvature will be horizontal or vertical.

Shear Studs Tab

...

Specifications

Don’t add studs

image-20240221-140101.pngImage Modified

If marked, the shear stud is not modeled under any circumstances.

Automatic stud placement

image-20240221-140109.pngImage Modified

If checked, the shear stud parameters in the slab settings are used in the modeling made using steel slab - composite options.

Always add studs

image-20240221-140118.pngImage Modified

If it is marked, the shear stud placement is done by taking the information from the 4 numbered slip nail parameters.

Shear stud parameters

image-20240221-140130.pngImage Modified

It becomes active if the always add shear stud option is selected, and it is used to determine parameters such as diameter, height, spacing, tensile strength.

...

...