It determines with parameters which criteria the program will comply with in reinforced concrete design and reinforcement placement stage.
...
Note |
---|
Parameters with the ( % ) sign mean the percentage expression of the rebar ratio. It is the ratio of the cross-sectional area of the reinforced concrete element to the rebar area expressed as a percentage. For example, when a “1” is written to the minimum percentage parameter, the rebar percentage is considered 1%. Since the percentage equivalent of a 0.01 rebar ratio is 1%, it is appropriate to write “1” to this parameter. |
...
Specifications |
---|
Concrete cover It is the distance from the center of gravity of the reinforcement to the outer face of the concrete. |
Min. tensile percentage |
In the tensile zone, give the minimum percentage value to be used in the rebar calculation. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result. |
Min. tensile interval In the tensile zone, give the smallest possible distance between two rebar bars. This value is taken into consideration in the selection of rebar. |
Max. tensile interval In the tensile zone, give the value of the greatest possible distance between two rebars. This value is taken into consideration in the selection of rebar. |
Min. transverse percentage Give the minimum percentage value to be used in horizontal rebars. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result. |
Max. transverse interval |
Give the smallest possible distance between two rebars for use in horizontal rebars. This value is taken into consideration in the selection of rebar. |
Max. transverse interval Give the maximum possible distance between two reinforcement bars to be used in horizontal reinforcements. This value is taken into consideration in the selection of reinforcement. |
Min. compression percentage |
In the pressure zone, give the minimum percentage value to be used in rebar calculation. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result. |
Min. compression interval Give the smallest possible distance between two reinforcing bars in the pressure zone. This value is taken into account in the selection of reinforcement. |
Max. compression interval Give the maximum possible distance between two reinforcing bars in the pressure zone. This value is taken into consideration in the selection of reinforcement. |
...
Next Topic