Connection Beam Parameters
With the Connection Beam Parameters command, the design parameters used in the Concrete Connection Beam Design, which are modeled together with Concrete Single Footing and Strip Foundation, are determined. Concrete cover, maximum and minimum reinforcement interval, etc. parameters are determined from the connection beam parameters window.
Location of Coupling Beam Parameters Dialog
Ribbon menu Analysis and Design tab Design Parameters title under connection beam ams parameters by clicking the command Connection Beams Parameters can be found in the dialogue.
Coupling Beam Parameters
It determines with parameters which criteria the program will comply with in concrete design and rebar placement stage.
Specifications |
---|
Concrete cover It is the distance from the center of gravity of the tension or compression rebar in the connection beam to the outer face of the concrete. |
Min. tensile percentage It is the parameter that determines the minimum rebar to be placed in the tensile zone in the connection beam. Under no circumstances can the rebar be less than the limit set by this parameter. |
Maximum percentage It determines the upper limit of the tensile rebar to be placed on the connection beam. Under no circumstances can the rebar exceed the limit specified by this parameter. If it is too much, the program will give the message "section is insufficient" for the connection beam where the maximum strength is higher. |
Min. B for double stirrup The connection beam width is compared with this parameter. As long as the width of the connection beam does not exceed the minimum width specified in this parameter, the tie beams are reinforced with a double arm stirrup. Otherwise, they are equipped with 2 double-armed stirrups. |
H for body reinforcement If the height of the connection beam is more than the value specified in this parameter, the web rebar is placed on the beam. |
Min. stirrup interval The spacing of the stirrup to be placed on the connection beam is chosen not to be less than the value specified in this parameter. |
Max. stirrup interval The spacing of the stirrup to be placed on the connection beam is chosen not to be more than the value specified in this parameter. |
Max. mounting interval It has no function for connection beam. |