  • In the absence of maximum in-plane compressive stress control, the slab thickness can be increased.

  • In the absence of maximum in-plane tensile and shear stress control;

    • Additional reinforcement can be added to the support area of ​​the relevant slab,

    • flooring reinforcement type can be selected as top flat+bottom flat ,

    • In the region where the tensile stress is high, a new reinforcement calculation axis can be defined and the amount of reinforcement in this region can be increased,

    • In the region where the tensile stress is high, a new slab can be defined with the help of the slab edge command and the reinforcement of this slab can be increased.

    • slab thickness can be increased,

    • the diameter of the floor reinforcements can be increased and the spacing can be reduced.

...