Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The reinforcement realization coefficient, which expresses the ratio of the existing reinforcement in the reinforced concrete walls and columns to the minimum reinforcement, will be determined. This coefficient used in determining the wall and column capacities cannot be greater than 1. This coefficient will be applied to all other walls and columns for which reinforcement has not been determined, and the possible reinforcement amounts will be determined. Only reinforcement required under vertical design loads will be used for beams.

Elements with corrosion in the reinforcement will be marked in the plan and this will be taken into account in the element capacity calculations.

  • No labels