After the architectural projects prepared with ideCAD Architecture are examined with ideCAD Structural, Analysis and Design is done and the analysis and design results are examined.
Click Structural Inspection in the ribbon menu .
From the Output topic, open the Steel All Failures list and click the PMM Failures command.
In the perspective view, the results of PMM failure with Axial force and biaxial bending control will be seen. It means that the selected deficiencies are not found in the green colored elements, and the selected deficiencies in the red colored elements are found in that element. Since the gray elements are concrete elements, this control is not applied.
Select the PMM ratios option from the list of design output.
The PMM ratio values of the steel elements will be seen in the perspective view. The PMM ratio greater than 1 means that the steel element is insufficient.
Select deflection failure limit from the list of design output .
In the perspective view, the steel elements with deflection control and their results will be seen.