You can examine the design results of steel elements in the Review Steel Design.ide10 project, which Analysis+Design has been completed |
Click Structural Inspection in the ribbon menu .
From the Output topic, open the Steel All Failures list.
Click the Steel PMM Failures command.
Steel PMM failure results will appear in the visualization window .
It means that there is no failure in the green colored elements, and there is a failure in the red colored elements.
Gray colored elements are concrete elements, this control is not applied.
Open the Design Output list from the visualization dialog.
Select the PMM rates line.
The PMM ratio values of the steel elements will be displayed in the visualization window.
A PMM ratio greater than 1 means that the steel element is insufficient.
Open the Design Output list.
Select the deflection failure line.
Deflection control of the steel elements and results will be seen.
Close the visualization dialog.
Go to the STORTY 1 CEILING page.
Click on the Steel tab in the ribbon menu .
Open the Steel list in the Design section and click the Column command.
The Steel Columns dialog will open.
In the dialog that opens, steel column sections, PMM ratios and combinations are listed.
Click the Details button.
The dialog with the design details of the steel column will open.
Close the detail dialog.
Click the OK button to close the Steel Columns dialog.
Open the Steel list in the ribbon menu and click the Beam command.
The Steel Beams dialog opens.
The dialog lists beam sections, PMM ratios, combinations and deflection control.
Click the Details button.
The dialog with the design details of the steel beam will open.
Close the detail dialog.
Click the OK button to close the Steel Columns dialog.