The project, which was prepared with ideCAD Architectural, was opened with ideCAD Structural. You can specify TDY conditions and the horizontal elastic design spectrum using the Analysis Settings Wizard.

  • Click on the Analysis Settings command.

  • In the General tab, check the 2018 TDY option.

  • Click the 2018 TDY Wizard for Analysis Settings button.

  • Click the Earthquake Ground Motion Level-2.

  • Click ZB as the site class.

  • Click the OK button to cancel the selections made on the next pages.

  • Click on the select point from map button.

  • On the map that opens, click on the location where the structure will be applied.

  • Click the offline button.

  • The Design Spectrum is defined according to DD-2 and DD-3.

  • Click the arrow to go to the next page.

  • Select the building risk category as BRC=3.

  • Seismic design category will be determined as DTS=2 .

  • Click the arrow to go to the next page.

  • Click on Story settings.

  • After checking the story settings, press the OK button to close the dialog.

  • The building height class will be defined as BYS=8 .

  • Click the arrow to go to the next page.

  • Performance level, KH and evaluation/design procedure are determined as DGT.

  • Click the arrow to go to the next page.

  • Select Reinforced Concrete as the structural system.

  • Select the Beam-and-slab structures and waffle slab as the slab type.

  • Select the Semi rigid diaphragm as the diaphragm modelling type.

  • Select the ductility of structure to High.

  • Select the structural type A11 for X direction.

  • Select the structural type A11 for Y direction..

  • Click the save icon to apply the parameters to the project.

  • Click the OK button to close the analysis settings dialog.


Follow the steps of the video below.

 