Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

For parallel reinforcement in a horizontal layer, clear spacing is controlled automatically

According to TS500, for longitudinal reinforcement in columns, pedestals, struts, and boundary elements in walls, clear spacing between bars is controlled automatically


Symbols

dagg = Nominal maximum size of coarse aggregate, in.
db = Nominal diameter of bar, wire, or prestressing strand,


According to TS 500 9.5.2, for parallel reinforcement in a horizontal layer, clear spacing is controlled automatically at least the greatest of

  • 25 mm

  • db

  • (4/3)dagg

According to TS 500 9.5.2, for longitudinal reinforcement in columns, pedestals, struts, and boundary elements in walls, clear spacing between bars is controlled automatically at least the greatest of

  • 40 mm

  • 1.5db

  • (4/3)dagg