The Complete Message:

The condition ∑Mdev> = 0.75Mo must be met in reinforced concrete structural systems with unidirectional gear floor with DTS = 1, 1a, 2, 2a, 3a or 4a.


For earthquake design class (DTS) 3a unidirectional geared reinforced concrete structural systems, the condition Mdev / M0> = 0.75 must be met.

According to article 4.3.4.6 of TBDY , ductility level should be provided in mixed structural systems (4.3).

                                                              ∑ M DEV ≥ 0.75 M o                                                       (4.3)

 

Possible solutions:

  • Shearwall / shearwall group can be added to the structural system until the 4.3 condition is met.

  • Solution can be made by choosing high ductility level. ( A14 or A15 )

  • Different flooring type can be selected.


Icons:

M DEV = In reinforced concrete and steel composite structural systems, the sum of the tipping moments caused by earthquake loads at the base of the reinforced concrete walls with high ductility level bond beam (with or without gaps) and central, eccentric or buckling-prevented steel braced frames

M o = Total tipping moment at the base from earthquake loads for the entire building