Group shear Capacity Design Ratios are calculated under the influence of axial force and biaxial bending using the fiber model. Group shear Capacity Design Ratios are given for shear reinforced concrete.

Possible Solutions

  • The thickness of the curtains or their length in plan can be increased to the curtain group.

  • Curtain cap area reinforcements can be increased.

  • Appropriate carrier system arrangement can be made.

  • Detailed information of the capacity ratios in Polygon Shears can be seen in the Capacity Design tab of the Shear Group Reinforced Concrete window . By using this section, it can be seen at which end of the polygonal curtain, under which combination effect, the capacity ratio is exceeded and can be intervened appropriately. At the same time , the Ratio-X and Ratio-Y values ​​specified in the Curtain Groups tab also show the largest capacity ratios in their dominant direction.

  • In the Capacity Diagrams tab of the Shear Group Reinforced Concrete window , the interaction diagram under the effect of axial force and biaxial bending in the 2 and 3 directions of the polygonal wall can be seen. In addition, the envelope area due to all loading combinations is also visible. By using the Capacity Diagrams tab, it can be determined under which force the curtain is forced.


  • No labels