Steel tie shear strength not satisfied.

Steel tie shear strength not satisfied.

This message is created by specifying the element name and floor on which it is located at the beginning of the report.

For example,

T01 BASE STORY Shear resistance not satisfied.

In steel element design, the shear design ratio is made according to the strong and weak axes according to CYTHYE 2016 (GKT & YDKT), AISC 360-16 (ASD & LRFD), or EN 1993-1-1 codes.

  • The steel element shear design ratio value should be less than 1.00.

Solutions:

  • Steel element cross-section can be enlarged.

  • Steel section web thickness can be increased.


Related content

Steel tie PMM ratio not satisfied.
Steel tie PMM ratio not satisfied.
More like this
Secondary steel beam PMM ratio not satisfied.
Secondary steel beam PMM ratio not satisfied.
Read with this
Steel column shear strength not satisfied.
Steel column shear strength not satisfied.
More like this
Secondary steel beam deflection limit exceeded.
Secondary steel beam deflection limit exceeded.
Read with this
Steel beam shear strength not satisfied.
Steel beam shear strength not satisfied.
More like this
Steel column section dimensions do not conform to Width-to-Thickness Ratios.
Steel column section dimensions do not conform to Width-to-Thickness Ratios.
Read with this