Earthquake overturning moment control in (X / Y) direction could not be achieved.


This message is given if the ratio of the sum of the overturning moments for the whole structure, the sum of the protective moments, is greater than 0.5.

Intermediate values ​​and control results are given in the Earthquake Tipping Control report.

Possible solutions:

  • Architecturally, the building floor area / height ratio can be reviewed.

  • Increasing the basic ampate size contributes to the solution.

  • Bringing the center of mass closer to the building geometric center. As the momentum decreases the column, the total moment of the overturner decreases.


See also:

Structure Tipping Moment Control