Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »


Location of Vault Settings Dialog

Vault, which appears after the Vault command is run, is also available in the auxiliary toolbar.

It can also be accessed by clicking the Objects / Roof / Vault / Vault Settings icon.

 

General Settings

Specifications

Explained

Vault name

The name of the vault is entered.

Number of pieces

When creating arc or curvilinear vaults, it is entered in how many pieces they will be formed. As the number of pieces increases, the vault lines get rounded.

Kot

The level of the lowest point of the vault is entered from the floor floor.

Thickness

The thickness of the vault coating is entered.

Custom size

If this option is selected, vault width and vault height can be entered in the information boxes on the right.

Original size

If this option is checked, the line, arc, etc. selected for the vault section. the dimensions of the objects are used.

Direction

It is selected by clicking one of the right or left options. It is determined whether the thickness of the vault (in the Z direction) will be inward or outward. If left is selected, the thickness is given outward, if right is selected, it is given inward.

spleen

The deviation of the vault in the plan is selected. Right, middle and left options determine where the vault axis will pass (where the vault will be defined). It refers to the vault defined from the upper right according to the viewing direction, defined in the middle and defined from the lower left. The nodes at the ends of the vault defined from below are located at the lower corners, and the upper corners defined from the top. The nodal points of the vault defined from the middle are located in the middle of the vault end edges.

Fringe type

The eaves geometry of the vault is determined.

textures

Specifications

Explained

Materiel

The material to be covered in the solid model of the vault is selected. The vault is covered with the selected material and displayed in the solid model as such.

Line Type

Line type of the line forming the vault is selected in the plan. Clicking the down arrow buttons to the right of the boxes opens the list of line types. From this list, the desired line type is selected by clicking the left mouse button.

Static

 

Specifications

Explained

Static material

Select the static material to be used in the vault element from the list. Static material can be defined as a reinforced concrete element under Materials in Building Tree.

Constant load

 

Fixed external loads, except the reinforced concrete weight of the vault, which consists of thickness, are entered.

Live load

The moving load value to be used in the calculation of the vault is entered.

Finite element width

Enter the maximum finite element width to be taken as basis in shell calculation. The program analyzes shells by dividing them into trapezoidal form finite elements. Finite element width is automatically adjusted according to the shell shape, provided that it does not exceed the value entered in this row.

Building Components

Add Building Components : Assigns the building materials defined for detailed building components metrics to the object.

  • Click on the building components button.

  • The Component Selection dialog will open.

  • In this dialog, click on the folder related to the material from the list on the left. Click on the material you want to use.

  • Set the parameters on the right.

  • Click the OK button. The "Component Selection" dialog will be closed. A summary line of the material will appear in the Building Components tab. More than one material assignment can be made to an object.     

The parameters available in the component selection dialog are:

In the usage section;

No change: The amount of material to be assigned for the object in question is marked when it is desired to be used in the size that was previously specified in the material definition.

Percentage ratio: This line is marked when it is desired to be used with the percentage of the amount previously determined in the material definition as much as the value entered in the "Value 1" line in the same dialog. For example, if the material quantity is 70, if the line “Value 1” says 40, it means the material amount will be used up to 40 * 70%.

Newly defined: This line is marked to use the amount entered in the "Value 1" line in the same dialog instead of the amount previously determined in the material definition.

Multiplier: This line is marked in order to use the value found at the end of the multiplication of the value entered in the "Value 1" line in the same dialog with the amount previously determined in the material definition.

Fractional: This line is marked so that the amount determined in the material definition before will be used as much as the fraction value formed by the values ​​entered in the "Value 1" and "Value 2" lines in the same dialog. "Value 1" is the denominator "Value 2" is the denominator.

Proportion: It is determined to what scale-area, circumference, length etc.-, region-side area, top, edge etc.- the material will be proportioned to. The content of the proportional list box is automatically determined according to the object and the size of the material. For example, a different list will be created if an operation is made for the column, a different list will be created for the library, a different list for the volume, and a different list for the field.

  • No labels