How does ideCAD control the torsional Irregularities, define strength reduction factors according to ASCE 7-16, for two earthquake directionsACI 318-19?

...

Tip
  • Strength Reduction Factors are calculated automatically.

...

Strength Reduction Factor for Earthquake-Resistant Structures

To resist earthquake effects, the The value of ϕ for shear will be is taken as described in ACI 21.2.4 for earthquake-resistant structures with elements in (a), (b), or (c):

...

It is stated in ACI 21.2.4.4 that the value of ϕ for shear will be 0.85 for beam-column joints and diagonally reinforced coupling beams.

...