Conditions to meet

  • It must be capable of providing a relative storey drift angle of at least 0.02 radians for limited ductility level and at least 0.04 radians for high ductility level.

Basics

  • The head plate welded joint is described in Annex 4A of DBYBHY 2007 , together with its geometry and additional requirements it must meet. However , this combination is not included in TBDY 2018 .

  • Due to the above situation, the geometry of this combination is created automatically as described in DBYBHY 2007 . However, design controls are made only according to ÇYTE 2018 GKT and YDKT methods. There is no control of the earthquake regulation.