Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

This message is created by specifying the element name and floor on which it is located at the beginning of the report.

For example,

T01 BASE STORY Beam deflection limit exceeded.

Deflection inspection of steel elements is carried out under dead loads, live loads and snow loads, depending on user control in accordance with the Design, Calculation and Construction Principles of Steel Structures (GKT and YDKT), AISC 360-16 (ASD and LRFD) or EN 1993-1-1 regulations. .

image-20240124-113109.png

Possible Solutions:

  • It can increase the dimensions of the element whose name and solid are given until the deflection condition is met.

  • It can be determined by checking the steel element deflection limit according to the given regulations.

  • The deflection value can be reduced by reducing the belt spacing.