Reinforced Concrete Column Design Limits per ACI 318-19 with ideCAD

Reinforced Concrete Column Design Limits per ACI 318-19 with ideCAD

How does ideCAD control reinforced concrete column design limits according to ACI 318-19?


  • Dimensional limits reinforced concrete columns are automatically controlled.

  • The user determines column dimensions.


Dimension limits of reinforced concrete columns of special moment frames

It is checked whether columns of special moment frames comply with the conditions given below:

  • The shortest cross-sectional dimension shall be at least 12 in.

  • The ratio of the shortest cross-sectional dimension to the perpendicular dimension shall be at least 0.4


 

Related content

Reinforced Concrete Column Design per ACI 318-19 §10, §18
Reinforced Concrete Column Design per ACI 318-19 §10, §18
More like this
Concrete Beam-Column Joint Shear Design per ACI 318-19 §15, §18.8
Concrete Beam-Column Joint Shear Design per ACI 318-19 §15, §18.8
Read with this
Column Reinforcement Limits per ACI 318-19 with ideCAD
Column Reinforcement Limits per ACI 318-19 with ideCAD
More like this
Concrete and Reinforcement Materials per ACI 318-19 with ideCAD
Concrete and Reinforcement Materials per ACI 318-19 with ideCAD
Read with this
Beam Design Limits per ACI 318-19 with ideCAD
Beam Design Limits per ACI 318-19 with ideCAD
More like this
Transverse Reinforcement (BRD) per ACI 318-19 with ideCAD
Transverse Reinforcement (BRD) per ACI 318-19 with ideCAD