Reinforced Concrete Column Design Limits per ACI 318-19 with ideCAD
Reinforced Concrete Column Design Limits per ACI 318-19 with ideCAD
How does ideCAD control reinforced concrete column design limits according to ACI 318-19?
Dimensional limits reinforced concrete columns are automatically controlled.
The user determines column dimensions.
Dimension limits of reinforced concrete columns of special moment frames
It is checked whether columns of special moment frames comply with the conditions given below:
The shortest cross-sectional dimension shall be at least 12 in.
The ratio of the shortest cross-sectional dimension to the perpendicular dimension shall be at least 0.4