Two-Way Slab Reinforcement Limits per ACI 318-19 with ideCAD
How does ideCAD control Two-Way slab reinforcement limits according to ACI 318-19?
Minimum area of flexural reinforcement, As,min is controlled and reported automatically.
The ratio of deformed shrinkage and temperature reinforcement area to gross concrete area are greater than or equal to 0.0018. It’s controlled automatically.
Symbols
Ag = gross area of concrete section, in.2
As,min = minimum area of flexural reinforcement in.2
Minimum flexural reinforcement in nonprestressed slabs
A minimum area of flexural reinforcement is satisfied near the slab's tension face in the span's direction.
As, min=0.0018Ag
Download ideCAD for ACI 318-19