DPT 1302-61 2019

Analysis settings that vary depending on the DPT 1302-61 2019 are explained in detail.

Download ideCAD for Seismic Code Design with DPT 1302-61 2019

Get Started for FREE Structural Engineering Software

DPT 1302-61 2019 Options Tab

Specifications

Specifications

Structural system type

The type of structural system for X and Y direction is selected in accordance with the design of the building.

Response modification coefficient

It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen.

Overstrength factor

It is the strength excess coefficient value. This row is automatically refreshed when the structural system type is chosen.

Deflection amplification factor

It is the deflection amplification factor value. This row is automatically refreshed when the structural system type is chosen.

Redundancy factor

It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen.

Accidental eccentricity ratio

The eccentricity ratio to be used during the analysis is given as a percentage.

Use custom vertical seismic load factor

If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used.

Structural system

If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements.

Building Risk Category

Building risk category value is selected from the list according to the purpose of use of the building.

Story drift check

Allowable story drift value is entered.

Response Spectrum Tab

Specifications

Specifications

Spectrum curve

 

The spectrum curve resulting from the settings is shown.

Function name

The name of the spectrum function.

Spectrum multiplier

Factor of spectrum function.

0.2 sec spectral acceleration (Ss)

0.2 sec spectral acceleration of spectrum function.

1 sec spectral acceleration (S1)

1 sec spectral acceleration of spectrum function.

Region

Select the region for the response spectrum from the list.

Damping ratio

Select the damping ratio for the response spectrum from the list.

Zone

Select the zone for the response spectrum from the list.

Site class

Site class is selected.

Short-period site coefficient (Fa)

Short-period site coefficient of spectrum function.

Long-period site coefficient (Fv)

Long-period site coefficient of spectrum function.

T0/Ts

Spectrum Characteristic Periods.


Download ideCAD for DPT 1302-61 2019

Get Started for FREE Structural Engineering Software

Next Topic

NSCP 2015