UBC 97 Uniform Building Code

UBC 97: 1997 Uniform Building Code

UBC 97 refers to the 1997 Uniform Building Code, one of the world's most widely used model building codes.

Download ideCAD for Seismic Code Design with UBC 97

Get Started for FREE Structural Engineering Software

Analysis settings that vary depending on the UBC 97 are explained in detail.

UBC 97 Options Tab in ideCAD Structural

Specifications

Specifications

Structural system type

The type of structural system for X and Y direction is selected in accordance with the design of the building.

Response modification coefficient

It is the response modification coefficient value. This row is automatically refreshed when the structural system type is chosen.

Overstrength factor

It is the strength excess coefficient value. This row is automatically refreshed when the structural system type is chosen.

Redundancy factor

It is the redundancy factor value. This row is automatically refreshed when the structural system type is chosen.

ELF Ct parameter

It is the ELF Ct parameter. This row is automatically refreshed when the structural system type is chosen.

Accidental eccentricity ratio

The eccentricity ratio to be used during the analysis is given as a percentage.

Use custom vertical seismic load factor

If checked, the custom vertical seismic load factor which entered in "factor to use (instead of 0.2 SDS)" line is used.

Structural system

If the building block consists of only concrete elements, Concrete; if it consists of only steel elements, Steel; Steel + Concrete option is selected if it consists of concrete and steel elements.

Building Risk Category

Building risk category value is selected from the list according to the purpose of use of the building.

Story drift check

Allowable story drift value is entered.

Response Spectrum Tab

Specifications

Specifications

Spectrum curve

The spectrum curve resulting from the settings is shown.

Function name

The name of the spectrum function.

Spectrum multiplier

Factor of spectrum function.

Soil profile type

Soil profile type is selected for the response spectrum.

Seismic zone factor

Seismic zone factor value is entered for the response spectrum.

Seismic source type

Seismic source type is selected for the response spectrum.

Distance to source [km]

Distance to source value is entered for the response spectrum.

User defined values

If this option is selected, parameters such as Ca, Cv, Na and Nv become active.

Ca/Cv

Seismic coefficient value is entered for the response spectrum.

Na

Near source factor use in the detemination of Ca for the response spectrum.

Nv

Near source factor use in the detemination of Cv for the response spectrum.


Next Topic

ASCE 7-16 Minimum Design Loads