9.3.1.3

9.3.1.3

  • Two different situations are taken into account when determining the internal forces for the design of the columns:

a) Shear force, axial force and bending moments computed by considering the load combinations which also includes the earthquake effect.

b) Axial force obtained by increasing the axial tensile and compressive forces by the overstrength factor D, regardless of the bending moment.



Related content

Internal Forces Based on Design Given in the Reports of the Columns of Special Steel Moment Frames
Internal Forces Based on Design Given in the Reports of the Columns of Special Steel Moment Frames
More like this
Design of Steel Columns for Combined Forces per AISC 360-16
Design of Steel Columns for Combined Forces per AISC 360-16
More like this
Conditions for Columns to be Stronger than Beams (Strong columns)
Conditions for Columns to be Stronger than Beams (Strong columns)