It cannot be used with high ductility level.

The Complete Message:

Structural systems with high ductility level cannot be used in reinforced concrete systems with unidirectional gear floor.


In the article 4.3.4.3 of TBDY 2018 , it is stipulated that the carrier systems consisting of reinforced concrete frames with single-directional geared floors with or without filling will be classified as structural systems with limited ductility level and will only be used in buildings with DTS = 3 and DTS = 4.

For this reason, high ductility level is not preferred for unidirectional gear floor systems.

Possible solutions:

  • A mixed selection of continuity level can be made by using the Analysis Settings / Earthquake Code wizard.

  • The type of flooring can be changed. Girder / Cassette Floor type can be applied instead of unidirectional gear flooring.


Next Topic

Systems with limited ductility level cannot be used for DTS 1a