Bond beam (Hollow) curtain adherence degree is not provided.

Bond beam (Hollow) curtain adherence degree is not provided.

The Complete Message:

The tie beam (Hollow) curtain adherence degree condition is not met for the (X / Y) direction.


4.5.4.5 TBDY by material bond beam (hollow) screen , Eq. (4.15) 'in the bond order is defined as the structural elements which satisfy the condition.

                                                                     Ω < 1/3 Think. (4.15)

If the condition defined in Equation (4.15) is not fulfilled, each part of the curtain is deemed to be a curtain without gap .

Your project is selected as the carrier system type hollow curtain system type and the degree of commitment of all curtains in the given direction is calculated greater than 1/3.

Solution:

  • The value can be increased by increasing the height of the tie beams.

  • Alternatively, instead of the tie beam (hollow) curtain system, one of the structural systems without gaps can be selected according to the ductility level with the Analysis Settings / Analysis Settings Wizard for the requested direction . A15 for systems of high ductility level, A22 for mixed systems, A24 for mixed single-line gear deck systems, A33 for limited systems.


Related content

Definition of Walls with Coupling Beam (4.5.4.1)
Definition of Walls with Coupling Beam (4.5.4.1)
More like this
Coupling Beam and Coupled Shearwall Modelling
Coupling Beam and Coupled Shearwall Modelling
More like this
In the shearwall group, the size ratio must meet (1/6) condition
In the shearwall group, the size ratio must meet (1/6) condition
More like this
Could not provide ∑Mdev> = Mo / 3 for curtains.
Could not provide ∑Mdev> = Mo / 3 for curtains.
More like this
Shearwall Web Reinforcement Detailing
Shearwall Web Reinforcement Detailing
More like this