The upper floor shearwall is thicker than the lower floor shearwall
The upper floor shearwall is thicker than the lower floor shearwall
This message is given if the same curtain is thicker on the upper floor than the lower floor.
Solution:
Enter the curtain thickness the same or smaller as the lower floor curtain and the thickness of the lower floor curtain as the upper floor curtain or thicker.
, multiple selections available,
Related content
Shearwall thickness cannot be less than 1/20 of the floor height.
Shearwall thickness cannot be less than 1/20 of the floor height.
More like this
Shearwall thickness cannot be less than 1/16 of the floor height.
Shearwall thickness cannot be less than 1/16 of the floor height.
More like this
The shearwall thickness cannot be less than 200 mm.
The shearwall thickness cannot be less than 200 mm.
More like this
The shearwall thickness cannot be less than 1/30 of the shearwall length.
The shearwall thickness cannot be less than 1/30 of the shearwall length.
More like this
The ratio of the thickness and length in the plan of shearwalls should be at least 6
The ratio of the thickness and length in the plan of shearwalls should be at least 6
More like this
The shearwall thickness cannot be less than 250 mm.
The shearwall thickness cannot be less than 250 mm.
More like this