In the shearwall group, the size ratio must meet (1/6) condition

In the shearwall group, the size ratio must meet (1/6) condition

The Complete Message:

In the curtain group, the dimension ratio of at least one curtain must meet (1/6) condition or define it as a polygon column.


In the TBDY 7.6.1.1 article, walls are defined as vertical bearing system elements whose long side to thickness ratio is at least six.

Each branch of curtains defined as curtain group must fulfill the condition of being curtain. If this condition is not met, this error message is given.

Solution :

  • Since the arms 1/6 ratio is not provided, the elements can be defined as polygons instead of defining each curtain piece.

  • Curtain arms can be entered instead of the condition of being 1/6 curtain. The lengths in the plan can be increased. (Can be made in sizes 25/150, 30/180 etc.)


Related content

The ratio of the thickness and length in the plan of shearwalls should be at least 6
The ratio of the thickness and length in the plan of shearwalls should be at least 6
More like this
The shearwall thickness cannot be less than 1/30 of the shearwall length.
The shearwall thickness cannot be less than 1/30 of the shearwall length.
More like this
TBDY 7.6.6.2 there are shearwalls that do not meet the strong shearwall requirements
TBDY 7.6.6.2 there are shearwalls that do not meet the strong shearwall requirements
More like this
Shearwall thickness cannot be less than 1/16 of the floor height.
Shearwall thickness cannot be less than 1/16 of the floor height.
More like this
The shearwall thickness cannot be less than 200 mm.
The shearwall thickness cannot be less than 200 mm.
More like this
There are shearwall groups that do not meet the capacity ratio.
There are shearwall groups that do not meet the capacity ratio.
More like this