Columns with a dimension ratio greater than 6 should be modeled as walls.

Columns with a dimension ratio greater than 6 should be modeled as walls.

In TBDY 2018 clause 7.6.1.1 , curtains are vertical structural system elements whose long edge to thickness ratio is at least six.

Accordingly, if the size ratio of a vertical element is greater than 6, it can be a curtain.

You are faced with this message because the vertical element with a dimension ratio greater than 6 in your project is defined using the "Column command".

Solution

  • Delete the floor and the column named, whose dimension ratio is greater than 6, and redefine it with the "Pitch command".


Related content

In the shearwall group, the size ratio must meet (1/6) condition
In the shearwall group, the size ratio must meet (1/6) condition
More like this
The ratio of the thickness and length in the plan of shearwalls should be at least 6
The ratio of the thickness and length in the plan of shearwalls should be at least 6
More like this
Shearwall thickness cannot be less than 1/16 of the floor height.
Shearwall thickness cannot be less than 1/16 of the floor height.
More like this
Could not provide ∑Mdev> = Mo / 3 for curtains.
Could not provide ∑Mdev> = Mo / 3 for curtains.
More like this
Could not provide >Mdev> = Mo / 6 for curtains.
Could not provide >Mdev> = Mo / 6 for curtains.
More like this
The shearwall thickness cannot be less than 200 mm.
The shearwall thickness cannot be less than 200 mm.