Well Foundation Design Settings Section

With the Well Foundation Design Settings, the design parameters used in the Concrete Well Foundation Design are determined. Concrete cover, maximum and minimum reinforcement interval, etc. parameters are determined from the Well Foundation Design Settings window.

image-20241003-120402.png

Specifications

Specifications

Concrete cover

It is the distance from the center of gravity of the rebar to the outer face of the concrete.

Min. tensile percentage

In the tensile zone, give the minimum percentage value to be used in the rebar calculation. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result.

Min. tensile interval

In the tensile zone, give the smallest possible distance between two rebars. This value is taken into consideration in the selection of rebar.

Max. tensile interval

 In the tensile zone, give the value of the greatest possible distance between two rebars. This value is taken into consideration in the selection of rebar.

Min. transverse percentage

Give the minimum percentage value to be used in horizontal rebars. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result.

Min. transverse interval

Give the smallest possible distance between two rebars to be used in horizontal rebars. This value is taken into consideration in the selection of rebar.

Max. transverse interval

Give the maximum possible distance between two rebars to be used in horizontal rebars. This value is taken into consideration in the selection of rebar.

Min. compression percentage

In the pressure zone, give the minimum percentage value to be used in rebar calculation. The entered value is multiplied by the sectional area and the rebar selection is made in a way that is not less than the result.

Min. compression interval

Give the smallest possible distance between two rebars in the pressure zone. This value is taken into consideration in the selection of rebar.

Max. compression interval

Give the maximum possible distance between two rebars in the pressure zone. This value is taken into consideration in the selection of rebar.