It cannot be used with high ductility level.
The Complete Message:
Structural systems with high ductility level cannot be used in reinforced concrete systems with unidirectional gear floor.
In the article 4.3.4.3 of TBDY 2018 , it is stipulated that the carrier systems consisting of reinforced concrete frames with single-directional geared floors with or without filling will be classified as structural systems with limited ductility level and will only be used in buildings with DTS = 3 and DTS = 4.
For this reason, high ductility level is not preferred for unidirectional gear floor systems.
Possible solutions:
A mixed selection of continuity level can be made by using the Analysis Settings / Earthquake Code wizard.
The type of flooring can be changed. Girder / Cassette Floor type can be applied instead of unidirectional gear flooring.