Dimensional Limits for Columns

Dimensional Limits for Columns

ICONS

A c = Gross cross-section area of ​​the column
E = Earthquake effect
Q = Live load effect
G = Constant load effect
N dm = Considering the live load reduction coefficients defined in TS 498, G and Q are vertical loads and E earthquake effects. Maximum of axial compressive forces calculated under joint effect G + Q + E
f ck = Characteristic cylinder compressive strength of concrete


7.3.1.1 - The smallest cross section dimension of rectangular columns shall not be less than 300 mm and circular columns diameter shall not be less than 350 mm.

7.3.1.2 - The gross cross-section area of ​​the column, N dm , taking into account the live load reduction coefficients defined in TS 498, the joint effect of vertical loads G and Q and E earthquake effect is the maximum of axial pressure forces calculated under G + Q + E. larger, it will satisfy the condition A cN dm /(0.40 f ck ).



Next Topic

Column Axial Force Control

Related content

Axial Capacity Insufficient in Column
Axial Capacity Insufficient in Column
More like this
Conditions for Columns to be Stronger than Beams (Strong columns)
Conditions for Columns to be Stronger than Beams (Strong columns)
More like this