Shearwalls with coupling beam is not found for A12

Shearwalls with coupling beam is not found for A12

Entire Message:

Shearwalls with coupling beam is not found at x/y direction.

 

A12 load-bearing system is defined in the earthquake code as buildings in which all the effects of earthquakes are covered by concrete shears with high ductility level .

Possible solutions:

  • For the selection of A12 carrier system type, it is possible to arrange the carrier system in such a way as to provide the conditions of the shearwalls with coupling beams (with gaps) in all of the shearwalls.

  • If any of the shearwalls in the system do not meet the conditions for shearwalls with coupling beams, A13 and A15 structural system types with no gaps can be selected in the Analysis Settings/TBDY 2018 Earthquake Code Wizard.

  • If shearwalls with or without gaps are not to be used, A11 structural system type can be selected for systems with high ductility level, and A31 structural system type can be selected for systems with limited ductility level.


Related content

Shearwalls with coupling beam is not found
Shearwalls with coupling beam is not found
More like this
Shearwalls with coupling beam is not found for A14
Shearwalls with coupling beam is not found for A14
More like this
Shearwall should be used for A22.
Shearwall should be used for A22.
More like this
A24 is selected. Shearwalls should be used.
A24 is selected. Shearwalls should be used.
More like this
Shearwall should be used for A15.
Shearwall should be used for A15.
More like this
Shearwall should be used for A14.
Shearwall should be used for A14.