Two-Way Slab Reinforcement Limits.

A minimum area of flexural reinforcement, is controlled and reported automatically.

The ratio of deformed shrinkage and temperature reinforcement area is controlled automatically.


International Design Codes

ACI 318-19 : Two-Way Slab Reinforcement Limits per ACI 318-19 with ideCAD

TSC 2018 : Punching Shear Stress at Critical Section (7.11.8)